環境

  • AFF-A320 です
  • プロセッサコントローラモジュール(PCM)
  • 電源装置(PSU)

問題

  • 障害のある PSU を交換したあとも、 HA の両方のノードで、交換した PSU のエラーが報告されます
  • 次の AutoSupport アラートが毎日表示されます

 HA Group Notification (CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2) ERROR 

  • 以下の EMS アラートは、 HA ペアの両方のノードで 1 時間ごとに表示されます
Sat Aug 21 00:27:05 +0530 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Power Out is Critical Low (0 W)
Sat Aug 21 00:27:05 +0530 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Curr Out is Critical Low (0 mA)
Sat Aug 21 00:27:05 +0530 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Volt Out is Critical High (12598 mV)
Sat Aug 21 00:27:05 +0530 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Power In is Critical Low (0 W)
  • MULTIFAULT「プラットフォームセンサー」がそれぞれのPSUに表示されます。
  • CriticalFruMultiFaultAlert システムヘルスアラート出力およびイベントログ内のノードレポート:

[Node-01: mgwd: callhome.hm.alert.critical:alert]: Call home for Health Monitor process cphm: CriticalFruMultiFaultAlert[XXXXXXX].

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.