In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

H610S : NVRAM エラーメッセージ

Views:
50
Visibility:
Public
Votes:
0
Category:
h-series
Specialty:
solidfire
Last Updated:

環境

NetApp H610S storage node

問題

This article addresses sporadic logging of NVRAM faults on H610S nodes, which often results in eviction of node's slice (metadata) drive

  • The node logs a variation of one of the following NVRAM (NVDIMM) faults:
  • NVRAM device critical={Device: 0x1000004 Key: armStatusSaveNArmed, Device: 0x1000004 Key: notEnoughEnergyForCatastrophicSave}
  • NVRAM device error={Device: 0x1000004 Key: energySourceTemperatureStatus Device: 0x1000004 CurTemp: Unknown HighTemp: Unknown LowTemp: Unknown Device: 0x1000104 CurTemp: Unknown HighTemp: Unknown LowTemp: Unknown} critical={Device: 0x1000004 Key: armStatusSaveNArmed, Device: 0x1000004 Key: notEnoughEnergyForCatastrophicSave, Device: 0x1000004 Key: warningThresholdExceeded}
  • NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support.  error={Device: 0x1000004 Key: energySourceLifetimeStatus} critical={Device: 0x1000004 Key: armStatusSaveNArmed, Device: 0x1000004 Key: energySourceHardwareFailure, Device: 0x1000004 Key: energySourceHealthAssessmentError, Device: 0x1000004 Key: noEnergySourcePresent, Device: 0x1000004 Key: notEnoughEnergyForCatastrophicSave, Device: 0x1000004 Key: warningThresholdExceeded}
  • NVRAM device warning={[Device: 0x1000105, Key: 0x700cc0]}
  • NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. warning={[Device: 0x1000005, Key: 0x300cc0]} error={[Device: 0x1000005, Key: 0x800000]}
  • platformHardwareEvent: Suppressing Nvdimm status result 1/3 as false positive
  • platformHardwareEvent: Nvdimm status has stabilized after 1 failed result(s)
  • The node's slice/metadata drive (drive 0) may be ejected, depending on error that is logged and Element OS version the node is running
If node is running  
Element 10.x Slice drive will most likely ありません be ejected, depending on timing factors within Element
Element 11.0 through 11.1 Slice drive 可能性があります be ejected, regardless of timing
Element 11.3.0 Slice drive 5 月 be ejected, depending on which of the above mentioned faults was experienced
  • NVRAM (NVDIMM) fault resolves on its own less than 5 minutes later
  • If node's slice/metadata drive (drive 0) was ejected, itwill not automatically re-add

Note: If these alerts are resolved, no further action from support is required

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support