Trident を 25.02.1 にアップグレードした後に外観上のエラーが発生
環境
- Trident 25.02.1
- トライデントのアップグレード
問題
- Trident 25.02.1 へのアップグレードが成功した後に外観上のエラーが発生する
ERRO Trident REST interface was not available after 180.00 seconds.
FATA Install failed; unable to upgrade connection: unable to upgrade: unable to negotiate protocol: client supports [v5.channel.k8s.io], server accepts [v4.channel.k8s.io v3.channel.k8s.io v2.channel.k8s.io channel.k8s.io]
unable to upgrade: unable to negotiate protocol: client supports [v5.channel.k8s.io], server accepts [v4.channel.k8s.io v3.channel.k8s.io v2.channel.k8s.io channel.k8s.io]; unable to upgrade connection: unable to upgrade: unable to negotiate protocol: client supports [v5.channel.k8s.io], server accepts [v4.channel.k8s.io v3.channel.k8s.io v2.channel.k8s.io channel.k8s.io]
unable to upgrade: unable to negotiate protocol: client supports [v5.channel.k8s.io], server accepts [v4.channel.k8s.io v3.channel.k8s.io v2.channel.k8s.io channel.k8s.io]; use 'tridentctl logs' to learn more. Resolve the issue; use 'tridentctl uninstall' to clean up; and try again.
- Trident の機能は期待どおりに動作し、PVC を作成および削除できます。