OnCommand Unified ManagerでMetroCluster クラスタの監視に失敗しました。エラー:「unexpected HTTP response code received for storage-bridge-get-iter」
環境
- ActiveIQ Unified Manager ( AIQUM ) 9.x
- MetroCluster
- ONTAP 9.x
問題
- AIQUM WebUIに次のエラーが表示されます。
Monitoring failed for cluster <cluster_name>. Reason: An internal error has occurred during MetroCluster component fresh.
Ocumserver.log
次のエントリが表示されます。
2020-04-09 00:19:00,028 ERROR [oncommand] [reconcile-1] [<clustre_name>] [c.n.dfm.collector.OcieJmsListener] Error during MetroCluster component monitoring : MetroCluster component monitoring failed. Zapi execution failed Unexpected HTTP response code received for storage-bridge-get-iter from <cluster_name>: 502
Zapi-outbound.log
次のエントリが表示されます。
20-04-09 00:13:59,353 DEBUG [collection-completion-0] Executing ZAPI request storage-bridge-get-iter to <cluster_name>:
[TRUNCATED]
2020-04-09 00:18:59,375 DEBUG [collection-completion-0] Received ZAPI response for storage-bridge-get-iter from <cluster_name>:
[TRUNCATED]
<results reason="The proxy server timed out waiting for the ontapi server at address <cluster_interface_ip_or_loopback_interface>" status="failed" errno="13114"/></netapp>
注:重要なログファイルとその場所はどれですか