コンピューティングノードのvmnicXが一時的に停止しています
環境
NetApp HCI コンピューティングノード
問題
vmnic2
vmnic3
一方のコンピューティングノードのまたはが一時的に停止しています。
例:
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499000us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: 1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 1 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499046us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 5 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499060us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic2 is down. Affected dvPort: 1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 5 uplinks up. Failed criteria: 128
2020-12-12T13:34:24.285Z: [netCorrelator] 6777049499451us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
2020-12-12T13:34:26.002Z: [netCorrelator] 6777059752759us: [esx.problem.net.dvport.redundancy.lost] Lost uplink redundancy on DVPorts: "1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is down.
2020-12-12T13:34:26.002Z: [netCorrelator] 6777059752926us: [esx.problem.net.dvport.redundancy.degraded] Uplink redundancy degraded on DVPorts: "vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is down.
2020-12-12T13:34:28.804Z: [netCorrelator] 6777054018733us: [vob.net.vmnic.linkstate.up] vmnic vmnic2 linkstate up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120739us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: 1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 2 uplinks up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120769us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 6 uplinks up
2020-12-12T13:34:28.906Z: [netCorrelator] 6777054120773us: [vob.net.dvport.uplink.transition.up] Uplink: vmnic2 is up. Affected dvPort: 1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6. 6 uplinks up
2020-12-12T13:34:30.002Z: [netCorrelator] 6777063752864us: [esx.clear.net.dvport.redundancy.restored] Uplink redundancy restored on DVPorts: "1524/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "vdrPort/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6", "1658/50 0a 9b 87 60 b6 8e 28-ff 4d c9 48 47 36 f4 d6". Physical NIC vmnic2 is up recently
2020-12-12T13:34:23.340Z cpu32:2023481)ixgbe 0000:18:00.0: vmnic2: Received unrecoverable ECC Err,initiating reset.
2020-12-12T13:34:23.340Z cpu53:66203)ixgbe 0000:18:00.0: vmnic2: Reset adapter