メインコンテンツまでスキップ

N2Dr3Xml20XmlValidateExceptionEでSRMテスト移行が失敗する

Views:
14
Visibility:
Public
Votes:
0
Category:
ontap-storage-replication-adapter<a>2009232773</a>
Specialty:
virt
Last Updated:

環境

  • Storage Replication Adapter(SRA)9.10
  • VMware Site Recovery Manager(SRM)8.5.
  • ONTAP 9

問題

SRMテスト移行が失敗し、N2Dr3Xml20XmlValidateExceptionE検証エラーが表示されます。

Operation Failed
A general system error occurred: N2Dr3Xml20XmlValidateExceptionE empty content is not valid for content model '(TargetDevice+)' (757)
[context]zKq7AVECAAQAAFE5JgEUdm13YXJlLWRyAACh3BxsaWJ2bWFjb3JlLnNvAAEQ8gFsaWJzcm0teG1sLnNvAALKxy5saWJ4ZXJjZXMtYy0zLjIuc28AAmelJgIwzCcClMUnAhmsJwItTC0By/UBA9pWC2xpYmRyLXN0b3JhZ2Utc3JhLnNvAANAWwsDDIcIA+k7CATNsgNsaWJkci12bWFjb3JlLnNvAAR6UgMAHWkxAHKFMQBeuUIFh38AbGlicHRocmVhZC5zby4wAAYPNg9saWJjLnNvLjYA[/context]
[backtrace begin]
 product: VMware vCenter Site Recovery Manager, version: 8.5.0, build: build-19282257, tag: vmware-dr, cpu: x86_64, os: linux, buildType: release
 backtrace[03] libvmacore.so[0x001CDCA1]
 backtrace[04] libsrm-xml.so[0x0001F210]
 backtrace[05] libxerces-c-3.2.so[0x002EC7CA]
 backtrace[06] libxerces-c-3.2.so[0x0026A567]
 backtrace[07] libxerces-c-3.2.so[0x0027CC30]
 backtrace[08] libxerces-c-3.2.so[0x0027C594]
 backtrace[09] libxerces-c-3.2.so[0x0027AC19]
 backtrace[10] libxerces-c-3.2.so[0x002D4C2D]
 backtrace[11] libsrm-xml.so[0x0001F5CB]
 backtrace[12] libdr-storage-sra.so[0x000B56DA]
 backtrace[13] libdr-storage-sra.so[0x000B5B40]
 backtrace[14] libdr-storage-sra.so[0x0008870C]
 backtrace[15] libdr-storage-sra.so[0x00083BE9]
 backtrace[16] libdr-vmacore.so[0x0003B2CD]
 backtrace[17] libdr-vmacore.so[0x0003527A]
 backtrace[18] libvmacore.so[0x0031691D]
 backtrace[19] libvmacore.so[0x00318572]
 backtrace[20] libvmacore.so[0x0042B95E]
 backtrace[21] libpthread.so.0[0x00007F87]
 backtrace[22] libc.so.6[0x000F360F]
[backtrace end]

SRA検出応答のTargetDevicesセクションが空です。

<sra:TargetGroups>
  <sra:TargetGroup key="//<YOUR_SVM>/<SOME_VOLUME>">
      <sra:TargetDevices>
         <sra:TargetDevice key="//<YOUR_SVM>/<SOME_VOLUME>"/>
         <sra:TargetDevice key="//<YOUR_SVM>/<SOME_VOLUME>"/>
         <sra:TargetDevice key="//<YOUR_SVM>/<SOME_VOLUME>"/>
      </sra:TargetDevices>
   </sra:TargetGroup>
   <sra:TargetGroup key="//<YOUR_SVM>/<SOME_VOLUME>">
      <sra:TargetDevices>
         <sra:TargetDevice key="//<YOUR_SVM>/<SOME_VOLUME>"/>
         <sra:TargetDevice key="//<YOUR_SVM>/<SOME_VOLUME>"/>
      </sra:TargetDevices>
   </sra:TargetGroup>
   <sra:TargetGroup id="//<YOUR_SVM>/<PROBLEM_VOLUME>" key="//<YOUR_SVM>/<PROBLEM_VOLUME>" state="read-write">
-->      <sra:TargetDevices/>   <--- Target Device info missing
   </sra:TargetGroup>
</sra:TargetGroups>

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.