環境
E5760
問題
- コントローラAのリブート後にファンエラーが検出されましたが、あとで自動的にリカバリされます。
- メジャーイベントログの例
A:2/15/23, 7:41:27 PM (19:41:27) 238 2606 Start-of-day routine begun - Shelf 99, Bay A
A:2/15/23, 3:50:55 AM (03:50:55) 235 2809 Controller shelf component changed to optimal - Shelf 99, Fan canister 1, Bay 2
A:2/15/23, 3:50:55 AM (03:50:55) 234 2809 Controller shelf component changed to optimal - None
B:2/15/23, 3:51:02 AM (03:51:02) 233 2809 Controller shelf component changed to optimal - Shelf 99, Fan canister 1, Bay 2
B:2/15/23, 3:51:02 AM (03:51:02) 232 2809 Controller shelf component changed to optimal - None
A:2/15/23, 3:09:13 AM (03:09:13) 42 280b Controller shelf component failed - Shelf 99, Fan canister 1, Bay 2 <--CRITICAL
A:2/15/23, 3:08:03 AM (03:08:03) 35 2606 Start-of-day routine begun - Shelf 99, Bay A