環境
BES-53248 クラスタスイッチ
問題
RCF スクリプトをコピーするときに、 BES-53248 クラスタスイッチから検証エラーが報告されます。
(Switch)#copy http://172.19.2.1/RCF-Cluster-HA.txt nvram:script RCF-Cluster-HA.scr
Management access will be blocked for the duration of the transfer
 Are you sure you want to start? (y/n) y
 HTTP Configuration Script transfer starting...
Validating configuration script...
Configuration script validation failed.
 Following lines in the script may have problem:
 Line 41:: passwords lock-out 0
 Line 55:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit
 Line 59:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit
 Line 68:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit
 Line 72:: police-simple rate-percent 60 64 conform-action transmit violate-action transmit
Total error Lines :: 5
 The file being downloaded has potential problems.
 Do you want to save this file? (y/n)