Brocade G610が複数回予期せずリブートした
環境
- Brocade G610
問題
- Brocade G610が明らかな理由なしに何度も予期せずリブートした
errdump -a
2022/02/08-19:04:19, [HAM-1004], 238, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]2022/02/28-09:36:49, [HAM-1004], 246, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]
2022/03/23-09:55:31, [HAM-1004], 261, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.psshowPower Supply #1 is OKfanshowFan 1 is Ok, speed is 7425 RPMFan 2 is Ok, speed is 7345 RPMFan 3 is Ok, speed is 7425 RPMFan 4 is Ok, speed is 7425 RPMsensorshowsensor 1: (Temperature) is Ok, value is 23 Csensor 2: (Temperature) is Ok, value is 23 Csensor 3: (Temperature) is Ok, value is 26 Csensor 4: (Temperature) is Ok, value is 25 Csensor 5: (Temperature) is Ok, value is 21 Csensor 6: (Temperature) is Ok, value is 19 Csensor 7: (Temperature) is Ok, value is 25 Csensor 8: (Temperature) is Ok, value is 22 Csensor 9: (Temperature) is Ok, value is 37 Csensor 10: (Fan ) is Ok,speed is 7425 RPMsensor 11: (Fan ) is Ok,speed is 7345 RPMsensor 12: (Fan ) is Ok,speed is 7425 RPMsensor 13: (Fan ) is Ok,speed is 7425 RPMsensor 14: (Power Supply) is Ok- 電源ケーブルが正しく接続されていることを確認し、スイッチに電源を供給するコンポーネント(ソケット、ライン、ケーブル、UPSなど)の正常性状態を確認。
- 電源ケーブルとソケットを 交換しても問題が持続する
- 同じ無停電電源装置(UPS)/回路の他のコンポーネントは影響を受けません。