Brocade G610が複数回予期せずリブートした
環境
- Brocade G610
問題
- Brocade G610が明らかな理由なしに何度も予期せずリブートした
errdump -a
2022/02/08-19:04:19, [HAM-1004], 238, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]
2022/02/28-09:36:49, [HAM-1004], 246, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]
2022/03/23-09:55:31, [HAM-1004], 261, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
psshow
Power Supply #1 is OK
fanshow
Fan 1 is Ok, speed is 7425 RPM
Fan 2 is Ok, speed is 7345 RPM
Fan 3 is Ok, speed is 7425 RPM
Fan 4 is Ok, speed is 7425 RPM
sensorshow
sensor 1: (Temperature) is Ok, value is 23 C
sensor 2: (Temperature) is Ok, value is 23 C
sensor 3: (Temperature) is Ok, value is 26 C
sensor 4: (Temperature) is Ok, value is 25 C
sensor 5: (Temperature) is Ok, value is 21 C
sensor 6: (Temperature) is Ok, value is 19 C
sensor 7: (Temperature) is Ok, value is 25 C
sensor 8: (Temperature) is Ok, value is 22 C
sensor 9: (Temperature) is Ok, value is 37 C
sensor 10: (Fan ) is Ok,speed is 7425 RPM
sensor 11: (Fan ) is Ok,speed is 7345 RPM
sensor 12: (Fan ) is Ok,speed is 7425 RPM
sensor 13: (Fan ) is Ok,speed is 7425 RPM
sensor 14: (Power Supply) is Ok
- 電源ケーブルが正しく接続されていることを確認し、スイッチに電源を供給するコンポーネント(ソケット、ライン、ケーブル、UPSなど)の正常性状態を確認。
- 電源ケーブルとソケットを 交換しても問題が持続する
- 同じ無停電電源装置(UPS)/回路の他のコンポーネントは影響を受けません。