Brocade G610の温度センサーが動作を停止しました
環境
- Brocade G610
- Brocade Fabric Operating System(FOS)9.x
問題
errdump
センサーおよびI2Cバスに関する問題を報告します。
2023/08/29-09:36:22, [EM-1014], 674, CHASSIS, ERROR, BrocadeG610, Unable to read sensor on Switch (-4).
2023/08/29-09:41:15, [EM-1029], 679, CHASSIS, WARNING, BrocadeG610, Switch, a problem occurred accessing a device on the I2C bus (-4). Operational status (10) not changed, access is being retried.
- 温度センサーの
Unknown
状態:
/fabos/cliexec/tempshow:
Sensor ID|Sensor Index|State |Centigrade |Fahrenheit |
----------------------------------------------------------------------
1 |0 |Unknown |N/A |N/A |
2 |1 |Unknown |N/A |N/A |
3 |2 |Unknown |N/A |N/A |
4 |3 |Unknown |N/A |N/A |
5 |4 |Unknown |N/A |N/A |
6 |5 |Unknown |N/A |N/A |
7 |6 |Unknown |N/A |N/A |
8 |7 |Unknown |N/A |N/A |
9 |8 |Unknown |N/A |N/A |
/fabos/cliexec/sensorshow:
sensor 1: (Temperature) is Unknown
sensor 2: (Temperature) is Unknown
sensor 3: (Temperature) is Unknown
sensor 4: (Temperature) is Unknown
sensor 5: (Temperature) is Unknown
sensor 6: (Temperature) is Unknown
sensor 7: (Temperature) is Unknown
sensor 8: (Temperature) is Unknown
sensor 9: (Temperature) is Unknown
sensor 10: (Fan ) is Ok,speed is 7425 RPM
sensor 11: (Fan ) is Ok,speed is 7425 RPM
sensor 12: (Fan ) is Ok,speed is 7507 RPM
sensor 13: (Fan ) is Ok,speed is 7507 RPM
sensor 14: (Power Supply) is Ok
haReboot
問題を解決できないなどのソフトリセット/ウォームリブートが正常に実行されない。- スイッチがサポートされているFOS上にある。