Brocade G610の温度センサーが動作を停止しました
環境
- Brocade G610
- Brocade Fabric Operating System(FOS)9.x
問題
errdumpセンサーおよびI2Cバスに関する問題を報告します。
2023/08/29-09:36:22, [EM-1014], 674, CHASSIS, ERROR, BrocadeG610, Unable to read sensor on Switch (-4).2023/08/29-09:41:15, [EM-1029], 679, CHASSIS, WARNING, BrocadeG610, Switch, a problem occurred accessing a device on the I2C bus (-4). Operational status (10) not changed, access is being retried.- 温度センサーの
Unknown状態:
/fabos/cliexec/tempshow:Sensor ID|Sensor Index|State |Centigrade |Fahrenheit |----------------------------------------------------------------------1 |0 |Unknown |N/A |N/A |2 |1 |Unknown |N/A |N/A |3 |2 |Unknown |N/A |N/A |4 |3 |Unknown |N/A |N/A |5 |4 |Unknown |N/A |N/A |6 |5 |Unknown |N/A |N/A |7 |6 |Unknown |N/A |N/A |8 |7 |Unknown |N/A |N/A |9 |8 |Unknown |N/A |N/A |/fabos/cliexec/sensorshow:sensor 1: (Temperature) is Unknownsensor 2: (Temperature) is Unknownsensor 3: (Temperature) is Unknownsensor 4: (Temperature) is Unknownsensor 5: (Temperature) is Unknownsensor 6: (Temperature) is Unknownsensor 7: (Temperature) is Unknownsensor 8: (Temperature) is Unknownsensor 9: (Temperature) is Unknownsensor 10: (Fan ) is Ok,speed is 7425 RPMsensor 11: (Fan ) is Ok,speed is 7425 RPMsensor 12: (Fan ) is Ok,speed is 7507 RPMsensor 13: (Fan ) is Ok,speed is 7507 RPMsensor 14: (Power Supply) is OkhaReboot問題を解決できないなどのソフトリセット/ウォームリブートが正常に実行されない。- スイッチがサポートされているFOS上にある。