メインコンテンツまでスキップ

snmpdの終了によりBrocadeスイッチを手動でリブートする必要がある

Views:
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

環境

  • ファブリックOS(FOS)v9.1.1a
  • Brocade G620

問題

  • errdump スイッチのリブートが必要なログを記録します。
2024/09/25-10:59:45 (UTC), [HAM-1009], 111826, FFDC | CHASSIS, CRITICAL, BrocadeG620, Need to MANUALLY REBOOT the system for recovery - auto-reboot is disabled.
  • errdumpall SNMPデーモンが終了したことを示します。
2024/09/25-10:57:30:285441 (UTC), [KSWD-1002], 493671/111798, FFDC | CHASSIS, WARNING, BrocadeG620, Detected termination of process snmpd:2737., hasm_swd.c, line: 235, comp:insmod, ltime:2024/09/25-10:57:30:283625
2024/09/25-10:59:45:861004 (UTC), [HAM-5014], 493704/0, CHASSIS, ERROR, BrocadeG620, Hasm Command Load timed-out. snmp ., hasm_sgi.c, line: 3244, comp:hamd, ltime:2024/09/25-10:59:45:859810
2024/09/25-10:59:45:861030 (UTC), [HAM-1007], 493705/111825, FFDC | CHASSIS, CRITICAL, BrocadeG620, Need to reboot the system for recovery, reason: Software Bootup Failure:LS config timed out., hasm_iot.c, line: 1569, comp:hamd, ltime:2024/09/25-10:59:45:860086
  • snmpd プロセスはdefunct です。
/bin/ps exfcl:
F  UID  PID  PPID PRI  NI   VSZ  RSS WCHAN  STAT TTY     TIME COMMAND
4   0  2542   1  20  0  54648 16520 poll_s Sl  ?      0:10 hasmd
0   0  2737  2542  20  0    0   0 exit  Z   ?     5673:47  \_ snmpd <defunct>

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.