メインコンテンツまでスキップ

Brocade 6510スイッチでPSU交換後にファンから問題が報告されています

Views:
46
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009255239</a>
Specialty:
san
Last Updated:

環境

Brocade 6510スイッチ

問題

  • スイッチのPSU交換後、PSUは正常であると報告 sensorshowpsshowfanshow しますが、内蔵ファンはで障害が発生していると報告し、出力します。

sensorshow    :
sensor  1: (Temperature) is Ok, value is 38 C
sensor  2: (Fan     ) is Ok,speed is 14673 RPM
sensor  3: (Fan     ) is Faulty
sensor  4: (Power Supply) is Ok
sensor  5: (Power Supply) is Ok

psshow    :
Power Supply #1 is OK
Power Supply #2 is OK

fanshow    :
Fan 1 is Ok, speed is 14673 RPM
Fan 2 is Faulty

 

  • errdumpは、以下のエラーが発生しています。

errdump:

2022/08/05-11:33:52, [EM-1037], 64940, CHASSIS, INFO, switch, PS 2 is no longer faulted.
2022/08/05-11:33:57, [FW-1011], 64943, FID 128, INFO, switch_default, Env Power Supply 2, is above high boundary(High=0, Low=1). Current value is 1 (1 OK/0 FAULTY).
2022/08/05-11:33:58, [FW-1011], 64944, FID 2, INFO, switch, Env Power Supply 2, is above high boundary(High=0, Low=1). Current value is 1 (1 OK/0 FAULTY).
2022/08/05-12:00:11, [HIL-1301], 64945, CHASSIS, WARNING, switch, 1 blower failed or missing. Replace failed or missing blower assembly immediately.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.