Brocade SFPは、スイッチエンドの不良なSFPが原因でLaser_Fltエラーを報告します
環境
- Brocade Fabric OS(FOS)
- Brocade Fibre Channel(FC)スイッチ
問題
switchshowでポートの状態はLaser_Flt
Index Slot Port Address Media Speed State Proto
============================================================
--Truncated--
20 1 20 701400 id N16 Laser_Flt FC
sfpshow出力では、Txが-inf、Rxが最適範囲内と表示されます
Port 41:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 6801001200000000 8,16,32_Gbps SM lw Long_dist
[...]
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000486-01
Vendor Rev: B
[...]
Temperature: 31 Centigrade
Current: 0.000 mAmps
Voltage: 3333.7 mVolts
RX Power: -0.7 dBm (843.9uW)
TX Power: -inf dBm (0.0 uW)
- portshow 出力結果は以下の通り:
portshow 1
portDisableReason: None
portCFlags: 0x1
portFlags: 0x4441
PRESENT U_PORT LED FAULT
LocalSwcFlags: 0x0
portType: 27.0
POD Port: Port is licensed
portState: 2 Offline
Protocol: FC
portPhys: 3 Laser_Flt
portScn: 2 Offline
port generation number: 76
state transition count: 18
- 「
Laser_Flt」状態でTxが-infと表示される場合、スイッチSFPに不具合があることを示しています - この問題をさらに特定するには、SFPを抜き差しして状態を確認してください。
- ポートで同じエラーが再び発生した場合は、解決策に進んでください。