メインコンテンツへスキップ

ケーブル障害が原因でBrocadeスイッチポートで低Rx電力が報告される

Views:
16
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

環境

Brocadeスイッチ

問題

  • sfpshow レポートの Rx値が低すぎます

Slot  5/Port 21:
=============
Identifier:  3   SFP
Connector:   7   LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 59    Centigrade
Current:    7.640   mAmps
Voltage:    3327.1  mVolts
RX Power:   -25.1   dBm (3.1  uW)
TX Power:   -1.3   dBm (743.9 uW)

  • ISLポートレポートのLow RX:

=============
Slot  7/Port 56:
=============
QSFP No: 14 Channel No:0
Identifier:  17   QSFP28
Connector:   12   MPO Parallel Optic
Transceiver: 2802404000000080 16,32_Gbps OM3 sw Short_dist
...
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000351-01
Vendor Rev:  A
...
Temperature: 46    Centigrade
Current:    6.948   mAmps
Voltage:    3306.9  mVolts
RX Power:   -7.9   dBm (160.7uW) 
TX Power:   -1.4   dBm (725.2 uW)

  • Enc_out portershowで報告されたエラー:
/fabos/cliexec/porterrshow : frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 27: 0 0 0 0 0 0 0 0 2.1g 0 0 0 0 0 0 0 0 0 0
  • リンクステートレコード(LSR )エラーがerrdumpで次のように報告されました。ISLポートの受信数はLowです。

2024/01/17-04:51:22 (IST), [FLOD-1007], 39239, SLOT 1 | FID 128, WARNING, H1NETZGEN6X8FQ03EC1, The LSR for reachable domain 160 reached the maximum age and has been removed from the LSDB.
2024/01/17-09:50:47 (IST), [FLOD-1007], 39244, SLOT 1 | FID 128, WARNING, H1NETZGEN6X8FQ03EC1, The LSR for reachable domain 160 reached the maximum age and has been removed from the LSDB.

  • ポートログに表示されるエラーメッセージ:

01:06:14.455991 SCN Port Offline;rsn=0x10004,g=0xa16 A2,P0 A2,P0 220 NA
01:06:14.455997 *Removing all nodes from port A2,P0 A2,P0 220 NA
01:14:41.344062 SCN LR_PORT(0);g=0xa16 A2,P0 A2,P0 220 NA 01:14:41.411152 SCN Port Online; g=0xa16,isolated=0 A2,P0 A2,P1 220 NA
01:14:41.411337 Port Elp engaged A2,P1 A2,P0 220 NA"

  • ITW errdump でポートに対して報告されたエラー:

2022/12/15-20:04:23, [MAPS-1003], 22076, SLOT 1 | FID 128, WARNING, Sify_X7_112_FAB2, slot3 port27, F-Port 3/27, Condition=ALL_OTHER_F_PORTS(ITW/min>21), Current Value:[ITW, 2310518947 ITWs], RuleName=defALL_OTHER_F_PORTSITW_21, Dashboard Category=Port Health.
2022/12/15-20:05:23, [MAPS-1003], 22078, SLOT 1 | FID 128, WARNING, Sify_X7_112_FAB2, slot3 port27, F-Port 3/27, Condition=ALL_OTHER_F_PORTS(ITW/min>21), Current Value:[ITW, 2061402242 ITWs], RuleName=defALL_OTHER_F_PORTSITW_21, Dashboard Category=Port Health 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.