メインコンテンツまでスキップ

実行コンフィギュレーションが正しくないスイッチについてClusterIfIfIslDownWarnが報告される

Views:
6
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • Cisco Nexusクラスタスイッチ
  • ONTAP 9

問題

  • 新しいRCFを適用したあとにクラスタからClusterIfIfIslDownWarnが報告される。

               Node: NetappNode1
               Alert ID: ClusterIfIslDownWarn_Alert
               Resource: Ethernet1/32
     Severity: Major
        Indication Time: Thu Mar 07 08:48:42 2024
               Suppress: false
            Acknowledge: false
         Probable Cause: The cable used to connect switch
                        "Cluster-sw02(FDXXXXXXY)/Ethernet1/32" to the
       ISL port might be faulty. For the port-channel, please
                         check each individual link.
        Possible Effect: Cluster redundancy might be lost.
     Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends.
                         2) Reconnect the ISL port using another cable. After
                         reconnecting it, verify whether the link of the ISL
                         port is up by executing the commands per the switch
     configuration guide or by checking whether the Link
                         status LED is on.

  • 実際のRCFファイルとスイッチからのshow running-confg コマンドの出力に不一致がある。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?