環境

  • Cisco Nexus 9336C-FX2
  • ONTAP 9

問題

  • スイッチポート1~10は既存のノードですでに使用されています
  • スイッチポート11~18を使用して新しいノードを追加するときにポートがリンクアップしない(err-disabled状態)
  • 影響を受けるポートについて、スイッチエラーが記録されました。

%ETHPORT-5-IF_HARDWARE: Interface Ethernet1/13, hardware type changed to 100G
%ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver on interface Ethernet1/13 is not supported
%ACLQOS-SLOT1-4-ACLQOS_OVER_THRESHOLD: Inst 1 Tcam 0 Bank 1's (Ingress L2 QOS [ing-l2-qos]) usage has reached its threshold
%ACLQOS-SLOT1-4-ACLQOS_OVER_THRESHOLD: Inst 1 Tcam 0 Bank 1's (Ingress L2 QOS [ing-l2-qos]) usage has reached its threshold (message repeated 1 time)
%ETHPORT-5-SPEED: Interface Ethernet1/13, operational speed changed to 100 Gbps
%ETHPORT-5-IF_DUPLEX: Interface Ethernet1/13, operational duplex mode changed to Full
%ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/13, operational Receive Flow Control state changed to off
%ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/13, operational Transmit Flow Control state changed to off
%ACLQOS-SLOT1-2-ACLQOS_OOTR: Tcam resource exhausted: Ingress L2 QOS [ing-l2-qos]
%ETHPORT-5-IF_SEQ_ERROR: Error ("Sufficient free entries are not available in TCAM bank") communicating with MTS_SAP_IPQOS_MGR for opcode MTS_OPC_ETHPM_PORT_BRINGUP (RID_PORT: Ethernet1/13)
%ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/13 is down (Error disabled. Reason:Sufficient free entries are not available in TCAM bank)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.