ノードダウンイベント中に報告されたSwitchIslIfDownWarn_Alert
環境
- ONTAP 9
- クラスタスイッチ
問題
ノードはノードダウンの状況で SwitchIslIfDownWarn_Alertを報告します:
 
 Node: node-05
 Alert ID: SwitchIslIfDownWarn_Alert
 Resource: port-channel1
 Severity: Major
 Indication Time: Fri Jul 26 08:00:36 2024
 Suppress: false
 Acknowledge: false
 Probable Cause: The cable attached to the ISL port "netappsw1(XXXXX)/port-channel1" with the description of "" might be faulty. For the port-channel, please check each individual link.
 Possible Effect: Inter- or Intra- cluster redundancy might be lost.
 Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends.
                     2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands per the switch configuration guide or by checking whether the Link status LED is on.