メインコンテンツへスキップ

クラスタからノードを削除した後にSwitchIfDead_Alertが表示される

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • スイッチドクラスタ

問題

  • 非ISLポートでHealth alert SwitchIfDead_Alertが表示されました:
Node::> system health alert show
Node: Node-01
Alert ID: SwitchIfDead_Alert
Resource: Ethernet1/7
Severity: Major
Indication Time: Tue Mar 25 17:19:34 2025
Suppress: false
Acknowledge: false
Probable Cause: The interface
Cluster-sw2(FOCXXXXXXXX)/Ethernet1/7 is up,
but it is not passing unicast traffic.
Possible Effect: The lack of transmit or receive traffic reported by
the switch can indicate issues with port-level or
switch-level data packet forwarding.
Corrective Actions: 1) Check interface counters and neighbor discovery information to verify the port's activity.
2) Check cluster and switch health status.
  • EMSログにメッセージが表示されます:
[Node-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIfDead_Alert , Alerting Resource = Cluster-switch(XXXXXXXXXX)/Ethernet1/7 raised by monitor ethernet-switch
  • 最近クラスタから削除されたが、まだクラスタスイッチに接続されているノード。
  • 古いノードで使用されているスイッチポートは、依然としてadmin upで健全です。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?