メインコンテンツへスキップ

ログ収集を無効にして古いアラートを削除したあともSwitchSSHAccess_Alertを実行

Views:
3
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • ONTAP 9
  • クラスタネットワークスイッチ
  • MetroCluster

問題

  • SwitchSSHAccess_Alert はNode-02にのみ表示され、永続的アラートの表には表示されますが、現在の健全性アラートの表には表示されません。
  •  システム構成に変更があったにもかかわらず、システムの更新後にアラートが再表示される
  •  SwitchSSHAccess_Alert  が最終的に返されるため、ログ収集の無効化と古いアラートの削除は永続的に成功しませんでした。

Site A::> show system health alert

Node: <node A 02>
Warning message ID: SwitchSSHAccess_Alert
Resource: Switch-A1
Severity: Minor
Display time: Tue Nov 12 14:42:04 2024
Suppress: false
Acknowledge: false
Probable cause: SSH access to the Ethernet failed. ONTAP cannot collect
collect switch logs.
Possible effect: Ethernet switch logs are not available, in particular via
AutoSupport messages for troubleshooting.

Workaround: 1) Ensure that the specified credentials are valid to access the switch and that the SSH connection to the switch is possible from the node.
to the switch is possible from the node on which cshmd is running.

 

Site B:> system health alert show

Node: <node B 02>
Alert ID: SwitchSSHAccess_Alert
Resource: Switch-B2
Severity: Minor
Indication Time: Tue Dec 10 11:15:19 2024
Suppress: false
Acknoledge: false
Probable Cause: Ethernet switch logs are not available, especially via Autosupport messages for troubleshooting.
Corrective Actions: 1) Ensure that the provided credentials are valid for accessing the switch and that SSH connectivity to the switch is possible from the node running cshmd.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.