メインコンテンツへスキップ

アグリゲートの Storage Efficiency を変更中にエラーが発生しました

Views:
8
Visibility:
Internal
Votes:
0
Category:
ontap-9
Specialty:
core<a>翻訳対象:2009068951</a><a />
Last Updated:

環境

  • ONTAP 9
  • FAS
  • Storage Efficiency

問題

AFF 以外のシステムでインライン重複排除のオプションを有効にするとエラーが表示される:
 

cluster_CLI::> run -node * "options sis.idedup_allow_non_aff_hya on"

2 entries were acted on.

Node: ClusterA-01
Warning: These diagnostic commands are for use by NetApp
     personnel only.
You are changing option sis.idedup_allow_non_aff_hya, which applies to
both members of the HA configuration in takeover mode.
This value must be the same on both HA members to ensure correct
takeover and giveback operation.

Node: ClusterA-02
Warning: These diagnostic commands are for use by NetApp
     personnel only.
You are changing option sis.idedup_allow_non_aff_hya, which applies to
both members of the HA configuration in takeover mode.
This value must be the same on both HA members to ensure correct
takeover and giveback operation.

 

::*> aggr efficiency modify -aggregate aggr2 -cross-volume-background-dedupe true Error: command failed: Error in modifying storage efficiency on aggregate "aggr2" Reason: Cross volume deduplication is supported only on volumes that are owned by nodes that are All-Flash optimized personality enabled.