クラスタスイッチのログ収集がサポートされない-中止、BES-53248スイッチ
環境
- ONTAP 9.11.1以前
- クラスタスイッチログの収集
- Broadcom BES-53248クラスタスイッチ
問題
- スイッチの手動ログ収集が次のエラーで失敗します。
ClusterA::> system cluster-switch log collect -device clustersw-01
clusterswitch-01Error: Cluster switch log collection not supported - aborting.
- サブシステムのスイッチヘルスが低下し、ヘルスアラートに対してSwitchAccess_Alertが報告される。
ClusterA::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
ClusterA::> system health alert show -instance
Node: Node-01
Monitor: ethernet-switch
Alert ID: SwitchAccess_Alert
Alerting Resource: CLUSTERSW-01
Subsystem: Switch-Health
Indication Time: Tue Jun 07 05:41:01 2022
Perceived Severity: Minor
Probable Cause: Login_attempts_failed
Description: Login failed to Ethernet switch "CLUSTERSW-01". Cannot collect tech-support logs.
Corrective Actions: 1) To set up public SSH key authentication on the Ethernet switch,
run the "system switch ethernet log setup-password" command.
ONTAP(R) software requires one-time use of the Ethernet switch's administrative login credentials
to set up the public SSH key for ONTAP access.
The administrative credentials will be discarded after the setup command is complete.
2) If public SSH key authentication is already configured, log in to the Ethernet switch
with administrative credentials from an SSH host or serial console to investigate the login failures.
3) To disable tech-support log collection, run the
"system switch ethernet log disable-collection"
command.
Possible Effect: Ethernet switch tech-support logs are not available in AutoSupport(R) messages for troubleshooting.
Acknowledge: false
Suppress: false
Policy: SwitchAccess_Policy
Acknowledger: -
Suppressor: -
Additional Information: Switch Name:CLUSTERSW-01
Switch Serial Number:xxxxxxxxxxxxx
Switch Previous Uptime:193 days 21:03
Switch Current Uptime:193 days 21:09
Switch Rebooted:false
Alerting Resource Name: CLUSTERSW-01
Additional Alert Tags: -