メインコンテンツへスキップ

MetroClusterに2つのノードを追加した際に生成されるDualControllerNonHa_Alert

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • Metrocluster IP
  • Metroclusterへの別のHAペアの追加(8ノードMCC-IP構成への増設)

問題

  • 既存のMetroclusterに新しいHAペアを追加すると、アラートが発生しました
::*> system health alert show
        Node: Node-01
      Alert ID: DualControllerNonHa_Alert
      Resource: Shelf 3.10
 Severity: Major
   Indication Time: Fri Nov 21 13:33:33 2025
      Suppress: false
     Acknowledge: false
   Probable Cause: Storage shelf 10 is connected to two controllers
           (Node-01, Node-02) that are not an HA pair.
   Possible Effect: Access to shelf 3.10 will be lost with a single
           controller failure.
 Corrective Actions: 1. Halt all controllers that are connected to shelf 3.10.
           2. Connect shelf 3.10 to both HA controllers following the guide applicable to your shelf.
           3. Reboot the halted controllers.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.