ATTOブリッジ7500でのFCポートのフラッピング
- Views:
- 2
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009935447</a>
- Last Updated:
環境
- MetroCluster FC
- ONTAP 9
- ATTO FibreBridge 7500N
問題
Bridge Symbolic Name Monitored Status By Vendor Model Bridge WWN Secure ------------------------ ------------- --------- ------- ------- ------ --------------------- ---------------- --------- ATTO_2000000000a0010 Bridge102fb2 true ok in-band Atto FibreBridge 7500N 2000000000a0010 false ATTO_2000000000a00d20 Bridge202fb7 true error in-band Atto FibreBridge 7500N 2000000000a0020 false
get FCPortErrors all ; Fibre Channel Error Counts ; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC ;========================================================================== 1 212446 1502160 80 3996267 0 2 1 4 0 54 0
ブリッジイベントログ
0217CEB 09:26:12 04/23/24 INFO FC Async Event, Link Down, PTP/Fabric, 16Gb on FC Port 1
217CEC 09:26:12 04/23/24 INFO FC Port 1 Link Down detected.
217CED 09:26:12 04/23/24 INFO FC Loop Is Not Operational on FC Port 1
217CEE 09:26:17 04/23/24 INFO FC Async Event, Link Up, PTP/Fabric, 16Gb on FC Port 1 2
17CEF 09:26:17 04/23/24 INFO FC Port 1 Link Up. Rate: 16Gb, Topology: ptp.
217CF0 09:26:17 04/23/24 INFO FC Loop Is Operational on FC Port 1