メインコンテンツまでスキップ

クラスタ間ポートの問題が停止しているため、InterclusterBrokenConnectionAlertが発生しました

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2010070073</a>
Last Updated:

環境

  • AFF / FAS / ASA
  • ONTAP 9
  • MetroCluster

問題

  • ログを確認したところ、EMSログで次のイベントが見つかりました。
[?]  Fri Jun 21 04:20:34 +0530 [Node-02: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0f: Link down, check cable.
[?]  Fri Jun 21 04:20:35 +0530 [Node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node BFLNTAPCLA-02, port e0f.
 
[?]  Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.noreach:notice]: Network port e0f on node Node-02 cannot reach its expected broadcast domain Default:Replication. No other broadcast domains appear to be reachable from this port.
 [?]  Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.skipped:notice]: Network port e0f on node Node-02 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
 [?]  Fri Jun 21 04:31:33 +0530 [Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: InterclusterBrokenConnectionAlert[Node-01].
 
  • スイッチのログから、受信電力が検出されていないことがわかりました。
# show interface ethernet 1/10 transceiver details
 
Ethernet1/10
 
SFP Detail Diagnostics Information (internal calibration)
  ----------------------------------------------------------------------------
         Current        Alarms          Warnings
         Measurement   High     Low     High      Low
  ----------------------------------------------------------------------------
  Temperature  43.48 C     75.00 C   -5.00 C   70.00 C     0.00 C
  Voltage     3.33 V     3.63 V    2.97 V    3.46 V     3.13 V
  Current     6.99 mA    12.00 mA   1.00 mA   11.50 mA    2.00 mA
  Tx Power    -4.01 dBm    5.39 dBm  -10.00 dBm   2.39 dBm   -6.00 dBm
  Rx Power     N/A     5.39 dBm  -12.75 dBm   2.39 dBm   -8.72 dBm

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.