メインコンテンツまでスキップ

MetroCluster IP cshm ClusterIfIslandDownWar_Alert

Views:
8
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • MetroCluster IP
  • ONTAP 9
  • Ciscoスイッチ

問題

  • EMS logs showメッセージ:

[Cluster01-N01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = Cluster01-SW01(FOC12345AU0)/port-channel1 raised by monitor ethernet-switch

 
  • system health alert show アラートを表示します。
Monitor      ethernet-switch
Alert ID      ClusterIfIslDownWarn_Alert
Alerting Resource Cluster01-SW01(FOC12345AU0)/port-channel1 & Cluster01-SW02(FOC54321AU0)/port-channel1
Subsystem     Switch-Health
Corrective Actions    1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands per the switch configuration guide or by checking whether the Link status LED is on.
 
  • switchコマンド show-port channel summary を実行すると、ポートチャネルにメンバーポートが表示されなくなります。
--------------------------------------------------------------------------------
Group Port-    Type   Protocol  Member Ports
Channel
--------------------------------------------------------------------------------
1   Po1(SD)   Eth    NONE    --
10   Po10(SD)   Eth    NONE    --
11   Po11(SD)   Eth    NONE    --

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.