MetroCluster構成の初期化中にSeagate SSDドライブでエラーが発生する
のしんだ
環境
- ONTAP 9
- ファブリックMetroCluster
- X319_SLNGE7T6ATE
- X371_SLNGE960ATE
- X319_SLNGE7T6ATE
問題
- ドライブがFailed -でサポートされていません
sysconfig -a
Cluster01::> system node run -node <node name> -command sysconfig -a
NETAPP X319_SLNGE7T6ATE NA53 0.0GB (0 0B/sect) (Failed-Unsupported)
- EMSでSSDドライブタイプX319_SLNGE7T6ATEが初期化に失敗する
Cluster01::*> storage disk error show
Disk Error Type Error Text
--------- ----------- --------------------------------------------
1.11.22 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
2.10.22 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
2.10.23 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
3.0.23 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
3.0.22 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
4.1.22 diskfail This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
Cluster01::*> disk show -container-type broken -fields model , type
disk model type
------ ---------------- ----
1.11.22 X319_SLNGE7T6ATE SSD
2.10.22 X319_SLNGE7T6ATE SSD
2.10.23 X319_SLNGE7T6ATE SSD
3.0.23 X319_SLNGE7T6ATE SSD
3.0.22 X319_SLNGE7T6ATE SSD
4.1.22 X319_SLNGE7T6ATE SSD