メインコンテンツへスキップ

ONTAPがMetroClusterのBrocadeスイッチステータスの監視に失敗する

Views:
22
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
metrocluster
Last Updated:

環境

  • ファブリック接続MetroCluster
  • MetroClusterバックエンド ファブリック スイッチ
  • Brocade FOS 8.2.x/9.0.x

問題

  • ONTAP Health Monitor レポート FabricSwitchUnreachable_Alert
  • storage switch showには、Monitor ステータスが false である不明なスイッチが表示されます。

ONTAP fail to monitor Brocade switch status in MetroCluster

  • MGWD レポート SNMP が Brocade スイッチで取得失敗:
00000314.00f72d18 08fc3b98 Mon Feb 27 2023 01:47:18 +08:00 [kern_mgwd:info:1993] 0x845ac7b00: 0: ERR: fabricdatacollector::storage_switch: failed to get symbolic name for Brocade_xx.xx.xx.xx switch, error = SNMP request timed out. No response was received from "Brocade_xx.xx.xx.xx" over SNMP community "public". {in isPresentInProfile() at src/tables/storage_switch.cc:1560}
  • Switch errdump -a で多数のレポートが報告される プロセス snmpd の終了が検出されたエラー:
2023/02/27-01:25:59, [KSWD-1002], 811, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:7821.
2023/02/27-01:29:58, [KSWD-1002], 812, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:7942.
2023/02/27-01:31:14, [KSWD-1002], 813, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8106.
2023/02/27-01:35:35, [KSWD-1002], 814, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8342.
2023/02/27-01:37:32, [KSWD-1002], 815, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8485.
2023/02/27-01:37:47, [KSWD-1002], 816, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8616.
2023/02/27-01:37:47, [HAM-1013], 817, CHASSIS, CRITICAL, BrocadeG610, Restartable daemon (snmp (pid=8616)) died too soon. Reboot/Failover manually if necessary.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.