Plexes fail during Motherboard replacement
Applies to
- MetroCluster IP
- Motherboard replacement
- SyncMirror Plex Failed
- ONTAP 9
Issue
- AutoSupport reports the events:
HA Group Notification from X_siteB_N1 (SYNCMIRROR PLEX FAILED) ALERT 
HA Group Notification from X_siteB_N1(Health Monitor process schm: DualControllerHa_Alert[xxxxxxxxxxxx) ALERT
HA Group Notification from X_siteB_N2(HA GROUP ERROR: DISK/SHELF COUNT MISMATCH) ERROR
HA Group Notification from X_siteB_N1(DISK REDUNDANCY FAILED) ERROR
HA Group Notification from X_siteB_N1(FILESYSTEM DISK NOT RESPONDING) ERROR
- EMS reports the following messages
Fri Aug 22 18:05:44 +0800 [X_siteB_N1: dmgr_thread: raid.notify.on.non.persistent.failure:debug]: Received SDM_NOTIFY_ON_NON_PERSISTENT_FAILURE for disk uid 6000C500:EC81BF43:500A0981:00000002:00000000:00000000:00000000:00000000:00000000:00000000, originating sysid 123456789.
Fri Aug 22 18:05:44 +0800 [X_siteB_N1: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk 0v.i2.1L26 Shelf 21 Bay 1 [NETAPP   X319_SLBPE7T6ATE NA51] S/N [HSR04KXK] UID [5000C500:EC81BF43:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is not responding
- SYSCONFIG-Rsection
Plex /X_siteB_N1_data_01/plex1 (offline, failed, inactive, pool1)
    RAID group /X_siteB_N1_data_01/plex1/rg0 (partial, block checksums)
      RAID Disk Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------     ------------- ---- ---- ---- ----- --------------    --------------
      dparity FAILED      N/A                        3650699/ -
      parity FAILED      N/A                        3650699/ -
      data     0v.i1.3L28P1 0v    21  3          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.3L47P1 0v    21  22         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (reconstruct stalled)
      data     0m.i1.1L30P1 0m    21  5          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.2L32P1 0v    21  7          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.0L33P1 0m    21  8          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.0L34P1 0m    21  9          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data     0v.i1.3L36P1 0v    21  11         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data     0v.i1.2L40P1 0v    21  15         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data     0v.i1.2L46P1 0v    21  21         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data     0m.i1.1L27P1 0m    21  2          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.1L31P1 0m    21  6          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.3L38P1 0v    21  13         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      Raid group is missing 11 disks.