MetroCluster のヘッドアップグレード手順中に SVM ( Vserver )が停止しました
に適用されます
- MetroCluster
- ONTAP 9.5+
- FC-VI リンクがケーブル接続されています
- 次のシーケンスを含む mgwd.log
has_remote_cluster_done_switchover was retried. Retry count : 9
has_remote_cluster_done_switchover failed with err = FCVI Interconnect might be down. For fabric configurations, use "storage switch add" to start monitoring the switches.
問題
- ヘッドアップグレード中、すべての SVM が停止状態になります。
- Vserver start コマンドがエラーで失敗する:
Failed to determine if the remote cluster has done a switchover. Reason :
Internal error occurred on node "ClusterA-02" in cluster "ClusterA".
Details: (FCVI Interconnect might be down. For fabric configurations, use
"storage switch add" to start monitoring the switches. Then run "storage switch
show -port" to verify that the status of the used port is "online", and run
"storage switch show -san-config" to verify that the fabric configuration
(vsan/zone) is appropriate. For Stretch configurations, verify the FCVI
cabling.). Are you sure you want to proceed? {y|n}: y