メインコンテンツまでスキップ

fcvi.qlgc.qpErr:ONTAPエンドのストレージ側でエラーを受信しました

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • ONTAP 9
  • ファブリック接続MetroCluster
  • Brocadeスイッチ

問題

  • EMS ログのNetApp Endに次のエラーメッセージが表示されます。

Sun Aug 18 18:12:16 -0700 [node3: xxx_main1: fcvi.qlgc.qpErr:error]: FC-VI adapter: FCVI driver on port 0e received QP Error. QP name = Control, QP index = 0xf, VI state = Error(state code = 0x3), sub-error = Timeout occured on the QP exchange(error code = 0xe). Remote node's system id = 538145405. This error has occured 132 times. 

  • disc c3 ポートのc3 timeout rx porterrshowBrocadeスイッチログのporterrshow に表示されます。

porterrshow     :
      frames    enc   crc   crc   too   too   bad   enc  disc  link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out  c3  fail   sync   sig          tx   rx   err   err
  0:   4.0g   1.4g   0    0    0    0    0    0    0   349.1k  0    0    0    0    0    0   846   0    0   

  • SFP RxおよびTXの値はsfpshow 出力で最適な範囲にあります。

Port  0:
=============
Current:    7.530   mAmps 
Voltage:    3344.0  mVolts 
RX Power:   -2.5   dBm (567.5uW) 
TX Power:   -2.9   dBm (511.6 uW) 

  • Frame unrouted detected エラーはerrdump  ログに記載されています。

2024/08/21-20:37:16, [AN-1014], 922785, FID 128, INFO, switcha, Frame unroute detected, tx port 0 rx port 0, sid 7xxxx0, did 70xx0, timestamp 2024-08-21 20:37:16 .
2024/08/21-20:37:40, [AN-1014], 922821, FID 128, INFO, switcha, Frame unroute detected, tx port 0 rx port 0, sid 7xxxx0, did 70xx0, timestamp 2024-08-21 20:37:40 .

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.