環境

  • MetroCluster
  • ONTAP 9

問題

  • ディスクへのすべてのパスが失われたため、ノードがパニック状態になりました。

Wed Jan 22 09:05:02 +0100 [NodeA2: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1c.
Wed Jan 22 09:05:02 +0100 [NodeA2: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1a.
Wed Jan 22 09:05:02 +0100 [NodeA2: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1b.
Wed Jan 22 09:05:02 +0100 [NodeA2: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1d

  • nvmm.mirror.aborting:debug すべてのノードで表示
  • パニックメッセージ:

Panic_Message: aggr aggr0_NodeA_02: raid volfsm, fatal multi-disk error..  Raid type - raid4, mirrored Group name plex0/rg0 state NORMAL. 3 disks failed in the group. Dis
Backtrace: sk_save_stackframes:kmod_dumper:dumpcore_on_dumpstack:doadump:kern_reboot:vpanic:panic:sk_panic:fmdisk_disk_failure:vol_process_mdp:vol_mdp_dump_core:volfsm_child_failed:raidfsm_precommit:raidfsm_precommit:mirrorobj_state_notify:raidfsm_precommit:plexobj_state_notify:raidfsm_precommit:groupobj_replace:groupobj_state_notify:raidfsm_precommit:config_disk_fail_obj:config_disk_fail_obj:config_disk_fail_obj:config_disk_fail_obj:config_disk_fail_reply:config_async_reply:config_thread:fork_exit:fork_trampoline_sk
OS Version (formatted): 9.13.1P10

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 