メインコンテンツへスキップ

CFBMC-2246:BMC の再起動中に BMC コンソールで特殊文字が入力されていると BMC がハングすることがある

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

問題

BMCのリブート中にBMCコンソールに予期しない/特殊文字が入力されると、BMCがハングする可能性があります。
これによりBMC HBT MISSEDが発生することがあります。
Thu Sep 22 13:37:30 +0000 [Node-01: servprocd: sp.servprocd.upd.evts:debug]: params:\{'reason': 'BMC update - Pre-update checks passed.'}
Thu Sep 22 13:37:30 +0000 [Node-01: servprocd: sp.servprocd.upd.evts:debug]: params:\{'reason': 'SP Firmware network update from 1.89 to 1.91 has been triggered.'}
Thu Sep 22 13:51:14 +0000 [Node-01: env_mgr: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
Thu Sep 22 14:13:18 +0000 [Node-01: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params:\{'reason': 'BMC update - Update failed after timeout.'}
Thu Sep 22 14:13:18 +0000 [Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
Thu Sep 22 14:17:51 +0000 [Node-01: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params:\{'reason': 'BMC update pre-update checks failed.'}
Thu Sep 22 14:17:51 +0000 [Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
Thu Sep 22 14:38:00 +0000 [Node-01: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params:\{'reason': 'BMC update pre-update checks failed.'}
Thu Sep 22 14:38:00 +0000 [Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
Thu Sep 22 14:41:18 +0000 [Node-01: env_mgr: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.