CHW-3310: AFF A90 SP HBT の欠落および停止(10 分以内に sp.ipmi.lost.shutdown)

Views:
1
Visibility:
Internal
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

問題

  • BMCステータスが不明なまま予期しないノードダウンが発生しました。例:

LOADER-B> bmc status
Firmware Version:   UnknownIPv4 Settings
Failed to get IPv4/IPv6 addressing enables: Unknown IPMI completion code.
Failed to get DHCP setting: Unknown IPMI completion code.
   MAC Address:   N/A - Error
   Using DHCP:    Failed to get DHCP setting: Unknown IPMI completion code.
N/A - Error
   IP Address:    Failed to get address: Unknown IPMI completion code.
N/A - Error
   Gateway:     Failed to get gateway: Unknown IPMI completion code.
N/A - Error
   Netmask:     Failed to get netmask: Unknown IPMI completion code.
N/A - Error
*** command status = Error(-1)

  • ONTAPイベントからSP HBTメッセージを検出しました。例:

cluster::> event log show
... EMERGENCY monitor.shutdown.emergency: Emergency shutdown: Environmental Reason Shutdown (System reboot to recover the SP)
... EMERGENCY sp.ipmi.lost.shutdown: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 10 minutes.
... ALERT     callhome. sp.hbt.stopped: Call home for SP HBT STOPPED
... ERROR     asup.post.drop: AutoSupport message (HA Group Notification from node_name (SP HBT STOPPED) ALERT) was not posted to NetApp. The system will drop the message.
... ERROR     asup.post.drop: AutoSupport message (HA Group Notification from node_name (SP HBT MISSED) NOTICE) was not posted to NetApp. The system will drop the message.