メインコンテンツへスキップ

クラスタネットワークスイッチで「SwitchPowerFail_Alert」が報告される

Views:
9
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • Cisco NX3232C / N9K-C9336C-FX2 クラスター ネットワーク スイッチ

問題

  • 「SwitchPowerFail_Alert」および"SwitchPsuFanNotOperational_Alert"がクラスタネットワークスイッチで報告されており、PowerSupplyを指しています
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
 
::> system health alert show
Node: Node-n09
Alert ID: SwitchPowerFail_Alert
Resource: PowerSupply-1
Severity: Major
Indication Time: Mon Oct 27 17:23:14 2025
Suppress: false
Acknowledge: false
Probable Cause: "PowerSupply-1" on switch
"switch1(FOCXXXXXXXX)" is missing or is
not operational.
Possible Effect: Power supply redundancy on switch
"switch1(FOCXXXXXXX)" might be lost.
Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
2) Ensure that the power cord is securely connected to
the power supply of the switch.
 
Node: Node-n09
Alert ID: SwitchPowerFail_Alert
Resource: PowerSupply-1
Severity: Major
Indication Time: Mon Oct 27 17:23:14 2025
Suppress: false
Acknowledge: false
Probable Cause: "PowerSupply-1" on switch
"switch2(FOCYYYYYYYY)" is missing or is
not operational.
Possible Effect: Power supply redundancy on switch
"switch2(FOCYYYYYYY)" might be lost.
Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
2) Ensure that the power cord is securely connected to
the power supply of the switch.
Node   DR-A900-MCC-02
Monitor: ethernet-switch
Alert ID: SwitchPsuFanNotOperational_Alert
Alerting Resource: DR-MCC-SW01(FLM2814034Z)/PowerSupply-2 Fan-1
Subsystem: Switch-Health
Indication Time: Wed Jun 24 02:04:17 2026
Perceived Severity: Major
Probable Cause: Out_of_service
Description: "PowerSupply-2 Fan-1" on switch "DR-MCC-SW01(FLM2814034Z)" is not functioning properly.
Corrective Actions    1) Use the switch CLI to verify that the fan is functioning at the expected speed. 2) Replace the fan, if it is not operational.
Possible Effect       Cooling of switch "DR-MCC-SW01(FLM2814034Z)" might be degraded.
Acknowledge FALSE
Suppress      FALSE
Policy  SwitchPsuFanNotOperational_Policy
Acknowledger
Suppressor
Additional Information       Switch Name: DR-MCC-SW01(FLM2814034Z) Switch Show Model: N9K-C9336C-FX2 Switch Serial Number: FLM2814034Z Fan Name: PowerSupply-2 Fan-1 Single Fan or Fan Tray: single Is PSU Fan: yes Fan Container Name: PowerSupply-2 Fan Status: not-operational Successive Warning Count: 943 Error Description: operStatus=3 Switch Fan Resource Status: ok
Alerting Resource Name     DR-MCC-SW01(FLM2814034Z)/PowerSupply-2 Fan-1
  • EMSログ:
Thu Oct 23, 2025 04:03:17 +0000 HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[switch1(FOCXXXXXX)/PowerSupply-1]) ALERT
Thu Oct 23, 2025 04:03:17 +0000 HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[switch2(FOCYYYYYY)/PowerSupply-1]) ALERT
 
::> system switch ethernet power show
 
                   Admin    Operational
Switch       Power Supply    Status   Status    Error
------------------ ----------------- ---------- -----------  ---------------
Switch1       PowerSupply-1   on     failed    offEnvPower
 
Switch1       PowerSupply-2   on     operational
 
Switch2       PowerSupply-1   on     failed    offEnvPower
 
Switch2       PowerSupply-2   on     operational
 
  • スイッチからの「show env」出力では、次の内容が報告されます:

switch1# show env
Fan:
---------------------------------------------------------------------------
Fan        Model         Hw    Direction     Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan2(sys_fan2)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan3(sys_fan3)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan4(sys_fan4)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan_in_PS1   --           --    back-to-front   Shutdown
Fan_in_PS2    --           --    back-to-front   Ok
Fan Zone Speed: Zone 1: 0x9a
Fan Air Filter : NotSupported

Power Supply:
Voltage: 12 Volts
Power            Actual        Actual     Total
Supply   Model       Output        Input     Capacity    Status
              (Watts )       (Watts )    (Watts )
-------  ----------  ---------------  ------  ----------  --------------------
1     NXA-PAC-650W-PE      0 W         0 W      0 W   Shutdown
2     NXA-PAC-650W-PE     99 W        110 W     650 W    Ok

switch2# show env
Fan:
---------------------------------------------------------------------------
Fan        Model         Hw    Direction     Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan2(sys_fan2)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan3(sys_fan3)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan4(sys_fan4)  NXA-FAN-30CFM-F    --    back-to-front   Ok
Fan_in_PS1    --           --    back-to-front   Shutdown
Fan_in_PS2    --           --    back-to-front   Ok
Fan Zone Speed: Zone 1: 0x9a
Fan Air Filter : NotSupported

Power Supply:
Voltage: 12 Volts
Power            Actual        Actual     Total
Supply   Model       Output        Input     Capacity    Status
              (Watts )       (Watts )    (Watts )
-------  ----------  ---------------  ------  ----------  --------------------
1     NXA-PAC-650W-PE      0 W         0 W      0 W   Shutdown
2     NXA-PAC-650W-PE     98 W        108 W     650 W    Ok

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
  • この記事は役に立ちましたか?