外部シェルフでACPエラーが報告される
環境
IOM12シェルフ
問題
EMS.logは両方のシェルフACPモジュールで障害を報告しています。例:
ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.callhome.shlf.fault:error]: Call home for SHELF_FAULT- CLIは、両方のACPモジュールが重大な状態であると報告します:
Cluster::> system node run -node <node name> -command storage show fault -vEnclosure Status: criticalChannel: 1bShelf: 24Shelf Type: DS224-12Product Serial Number: XXXXXXXXXXXXXXXModule Type: IOM12Vendor Unique Element 85-IOM12: (ACP)Element Status Status Bytes Status Descriptions1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL- ACPの無効化/再有効化後も問題が残る
- シェルフモジュールの再装着後も問題が残る
- シェルフモジュールの交換後も問題が残る
- シェルフの電源サイクル後も問題が残る