AFF A250ノードが電源喪失によりダウン
環境
- AFF A250
- BMC FW 15.4
問題
- AFF A250ノードが電源の問題を示すログとともにダウンしました
1a2 | 01/01/2000 | 00:00:37 | Battery #0x4f | State Deasserted 1a3 | 01/01/2000 | 00:00:21 | Battery #0x4a | State Deasserted 1a4 | 01/01/2000 | 00:00:21 | Battery #0x4b | State Asserted 1a5 | 01/01/2000 | 00:00:22 | Battery #0x4c | State Asserted 1a6 | 01/01/2000 | 00:00:22 | Battery #0x4d | State Deasserted 1a7 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1a8 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1a9 | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1aa | 01/01/2000 | 00:00:22 | Other FRU #0x50 | 1ab | 01/01/2000 | 00:00:28 | Power Supply #0x20 | Presence detected | Asserted 1ac | 01/01/2000 | 00:00:28 | Power Supply #0x25 | Presence detected | Asserted 1ad | 01/01/2000 | 00:00:37 | Battery #0x4f | State Deasserted 1ae | 01/01/2000 | 00:05:37 | Power Unit #0x60 | Power cycle | Asserted 1af | 01/01/2000 | 00:05:55 | System Event #0xff | Timestamp Clock Sync | Asserted 1b0 | 12/21/2021 | 02:40:22 | System Event #0xff | Timestamp Clock Sync | Asserted 1b1 | 12/21/2021 | 02:41:32 | Power Unit #0x60 | Power off/down | Asserted
- パートナーノードには電源アラートが表示されません。
- ダウンしたノードは手動でONTAPを起動する必要があります。ONTAP
- ノードを起動した後、BMCから電圧アラートが表示されます。
1bd | 01/02/2022 | 19:24:46 | Voltage #0x30 | Upper Non-critical going high 1be | 01/02/2022 | 19:26:54 | Voltage #0x30 | Upper Non-critical going high 1bf | 01/02/2022 | 23:16:24 | Voltage #0x30 | Upper Non-critical going high 1c0 | 01/02/2022 | 23:18:33 | Voltage #0x30 | Upper Non-critical going high 1c1 | 01/03/2022 | 06:14:46 | Voltage #0x30 | Upper Non-critical going high 1c2 | 01/03/2022 | 06:16:54 | Voltage #0x30 | Upper Non-critical going high