AFF A320は、nvmem .battery .wrongChargeの実行後にシャットダウンします
環境
- AFF A320
- ONTAP 9
問題
のあとにノードがシャットダウンする nvmem.battery.wrongCharge:alert
- クラスタ内の1つのノードに対するEMSメッセージ:
Sat Dec 19 16:23:27 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
... (repeated hourly)
Sun Dec 20 15:23:38 +0100 [CLUSTERBA-CTRLA: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 60 minutes.
Sun Dec 20 15:24:18 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
Sun Dec 20 16:22:30 +0100 [CLUSTERBA-CTRLA: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery charging current failed)
- NVMEMバッテリのプラットフォームセンサー出力:
Battery Charge Failed? discrete fault normal TRUE
Battery Capacity Message discrete failed failed
Bat Curr current normal -40 mA
Bat Charging State discrete fault normal WRONG_CHARGE
- サービスプロセッサファームウェアと内部スイッチファームウェアが最新バージョンに更新されます。
- BMCシステムログ出力:
Jan 7 14:17:14 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 24 hours)
Jan 7 14:17:46 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
Jan 7 15:17:20 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 23 hours)
Jan 7 15:17:47 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
...
- カウンタが24時間に達すると、ノードがシャットダウンします