メインコンテンツまでスキップ

AFF A900がバッテリ(充電FETオフ)の警告を報告する

Views:
7
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009942804</a>
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • AFF A900
  • BMCファームウェア16.5

問題

  • 次のバッテリ充電 FET エラーがイベントログに記録されます。

[Node-01: env_mgr: nvram.battery.chargeFET.off:error]: The NVRAM battery charge FET is off. To prevent data loss, the system will shut down in 24 hours.
[Node-01: env_mgr: nvram.battery.chargeFET.normal:info]: The NVRAM battery charge FET is on.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (charge FET off) WARNING.

  • SP-LATEST-IPMI AutoSupportのセクションで、NVRAMバッテリの障害LEDが点灯していることを確認します。

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                    fault reason                   count  time             
---- ------- ----                   -------------                   ------ -----          
3   bmc    /chassis-1/controller-b/nvbatt-1     Environmental Condition by env_mgr        1    Mon Feb 12 10:40:08 2024

Fault Lights On:
       /chassis-1                                        1    
       /chassis-1/controller-b                                  1    
       /chassis-1/controller-b/nvbatt-1                            1    

  • BMCセンサーから次の情報が報告されます。

DCPM:

Bat_Status       | 0x0        | discrete   | Chrg FET  | na        | na        | na        | na           

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
Bat FRU Fault LED             ON
Battery Capacity Message failed        --
Battery RemCap Desc            READY
Battery Charge Failed?           TRUE

Bat Power Fault               GOOD
Bat Dcharge FET                ON
Bat Charge FET              OFF
Bat Pack Invalid               OK
Bat Learning Active             OFF

  • BMCファームウェアが最新バージョンである。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.