メインコンテンツへスキップ

断続的な HA グループ通知(CHASSIS POWER SUPPLY OFF:PS 1)エラー

Views:
30
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
HW
Last Updated:

環境

  • ONTAP 9
  • AFFシステム
  • ASAシステム
  • FASシステム

問題

  • EMS-LOG-FILE.gmz内のエラーは、最終的には解消されます
[node-4: env_mgr: monitor.chassisPowerSupply.off:debug]: Chassis power supply 1 off.
[node-4: monitor: monitor.globalStatus.critical:debug]: Power Supply Status Critical: PSU1. Chassis temperature is too low.. 
[node-4: wafl_exempt05: wafl.vol.snap_create.done:debug]: params: {'type': 'Volume', 'owner': '', 'vol': 'repo', 'app': '', 'volident': '@vserver:8dfcab95-ff03-11ed-b99e-d039ea53839c', 'run_time': '25339'}
[node-4: env_mgr: monitor.chassisTemperature.ok:debug]: Chassis temperature is ok.
[node-4: env_mgr: monitor.chassisTemperature.cool:debug]: Chassis temperature is too cool: PSU1 Hot is critical low (0 C).
[node-4: env_mgr: monitor.chassisPowerSupply.degraded:debug]: Chassis power supply 1 is degraded: PSU1 In Fault is FAULT
[node-4: monitor: monitor.globalStatus.critical:debug]: Power Supply Status Critical: PSU1. 
[node-4: env_mgr: monitor.chassisPowerSupply.degraded:debug]: Chassis power supply 1 is degraded: PSU1 Hot is Critical Low (0 C)
[node-4: env_mgr: monitor.chassisPowerSupply.degraded:debug]: Chassis power supply 1 is degraded: PSU1 Fan is Critical Low (0 RPM)
[node-4: env_mgr: monitor.chassisPowerSupply.off:debug]: Chassis power supply 1 off.
[node-4: monitor: monitor.globalStatus.critical:debug]: Power Supply Status Critical: PSU1. Chassis temperature is too low.. 
[node-4: env_mgr: monitor.chassisPowerSupply.ok:debug]: Chassis power supply 1 is OK.
[node-4: power_low_monitor: monitor.chassisPowerSupplies.ok:debug]: Chassis power supplies OK.
[node-4: monitor: monitor.globalStatus.ok:debug]: The system's global status is normal. 
[node-4: env_mgr: callhome.chassis.ps.ok:debug]: Call home for CHASSIS POWER SUPPLY OK: PS 1

 
または
 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 In Volt is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 In Curr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 12V Out Volt is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 12V Out Curr is Unreadable
[Node-01: env_mgr: callhome.chassis.ps.replace:error]: Call home for CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 In Pwr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Out Pwr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 2 is OK.
[Node-01: env_mgr: callhome.chassis.ps.ok:notice]: Call home for CHASSIS POWER SUPPLY OK: PS 2

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.