PSU の交換後も、シャーシの障害が原因で警告 LED が引き続き点灯します
に適用されます
FAS8040
問題
- シャーシの電源装置( PSU )の破損について、次のアラートが報告されます。
CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2) WARNING
- EMSログ ファイル
[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Power Output has failed
[env_mgr: callhome.chassis.ps.replace:error]: Call home for CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2
- SP 最新のイベントログファイル
Record 305: [Agent.notice]: 561.610: 14 : Attention LED (at Midplane) asserted
Record 306: [Agent.notice]: 141.633: 14 : Attention LED (at Midplane) de-asserted
Record 308: [Agent.notice]: 538.865: 4 : AC Power Loss Signal PSU2 de-asserted
Record 309: [Agent.notice]: 661.755: 6 : DC Power OK PSU2 de-asserted
Record 310: [Agent.notice]: 661.760: 10 : Power Supply Fault LED PSU2 asserted
Record 311: [Agent.notice]: 774.741: 14 : Attention LED (at Midplane) asserted
Record 312: [IPMI.notice]: 3500 | 02 | EVT: 0300ffff | PSU2_Pwr_In_OK | Assertion Event, "State Deasserted"
- PSU は既に交換済みで、電源装置のエラーが発生しています その電源装置で持続します