メインコンテンツまでスキップ

AFF-A400 では警告 LED が点灯したままになります

Views:
149
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • AFF-A400
  • FAS8300

問題

  • BMCの自動アップグレードがセンサーポリシーと競合状態になります。
  • EMSの表示内容:

[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ ABC in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ DEF in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ GHI in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ KLM in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor P1V05 PCH in the controller module is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Inlet) is not readable.
[env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Outlet) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp1) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp3) is not readable.
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[env_mgr: monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
[env_mgr: monitor.chassisPower.ok:notice]: Chassis power is OK.

  • system fru led show all 表示内容 LED_SYSTEM_ATTEN_01 is on

0  LED_SYSTEM_LOCATION_01 is off
1  LED_SYSTEM_ATTEN_01 is on
2  LED_CONTROLLER_ATTEN_01 is off

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.