メインコンテンツへスキップ

BMC 16.8へのアップグレードにより、PSU3およびPSU4に障害が発生する可能性があります

Views:
1
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

環境

  • AFF A900/FAS9500
  • ONTAP 9
  • BMCファームウェア 16.8

問題

  • AFF A900またはFAS9500をBMCファームウェア16.8にアップグレードした後、一部のシステムでPSU3とPSU4の故障が報告される場合があります

    •     EMS ログ:
      Wed Apr 15 14:24:25 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Volt is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 AC In Curr is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Volt is Unreadable Wed Apr 15 14:24:26 -0700 [rno2-cdot33-05: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 3 is degraded: PSU3 12V Out Curr is Unreadable
      Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Volt is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 AC In Curr is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Volt is Unreadable Wed Apr 15 22:03:35 -0700 [rno2-cdot33-06: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 4 is degraded: PSU4 12V Out Curr is Unreadable

      Autosupport の SP-Latest-IPMI セクション(影響を受ける特定のセンサーは以下)。出力はパートナー PSU4 と同じです)

      PSU3_Status | 0x0 | discrete | AC OK | na | na | na | na PSU3_12V_OP_I | na | Amps | na | 0.000 | 0.000 | 140.000 | 144.000 PSU3_12V_OP_V | na | Volts | na | 10.980 | 11.400 | 12.900 | 13.500 PSU3_AC_IP_I | na | Amps | na | na | na | 14.000 | 14.980 PSU3_AC_IP_V | na | Volts | na | 88.000 | 90.000 | 255.000 | 255.000 PSU3_Fault | na | discrete | na | na | na | na | na

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.