環境

  • NetApp FAS500F
  • ONTAP 9.13.1P4
  • Baseboard Management Controller(BMC)

問題

  • BMC ファームウェアをバージョン 15.11 から 15.13 に更新した後、node-01 の BMC への SSH アクセスが失敗します(接続がタイムアウトし、エラーメッセージは表示されません)。
  • system service-processor image show -instance はプライマリイメージが 15.13 であることを示していますが、LastUpdateStatusfailed です。

::> system service-processor image show -instance

        Node: node-01
        Image: primary
        Type: BMC
    Image Status: installed
  Is Image Current: true
  Firmware Version: 15.13
Firmware Autoupdate: true
 Last Update Status: failed

        Node: node-01
        Image: backup
        Type: BMC
    Image Status: installed
  Is Image Current: false
  Firmware Version: 15.11
Firmware Autoupdate: true
 Last Update Status: failed

  • 健康警報SPAutoUpgradeFailedMajorAlertがアクティブです。

::*> system health alert show

     Node: node-01
   Alert ID: SPAutoUpgradeFailedMajorAlert

  • system service-processor showステータスが true かつオンラインであることを示します。

::> system service-processor show

Node        Type Status  Configured Firmware Version IP Address
----------------------------------------------------------------------
node-01 BMC online  true     15.13       10.23.45.678

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.