シャーシの電源装置のデグレード:修正バージョンのCFBMC-5688を実行中
環境
- AFF A70
- AFF A90
- ONTAP 9
- サービスプロセッサバージョン 18.3P1以降
問題
- システムがPSU問題を報告しています。
ems-logは
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Curr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 12V Out Volt is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 12V Out Curr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Pwr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Out Pwr is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Volt is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Curr is Unreadable
[Node-01: env_mgr: callhome.chassis.ps.degraded:error]: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 1SP-IPMIレポート
PSU1 BADPSU1 FRU invalid --PSU1 Status normal 5 -- -- -- --PSU1 Present PRESENTPSU1 Output OK FAULTPSU1 Input OK FAULTPSU1 In Volt not_available -- mV 84000 mV 90000 mV 264000 mV 276000 mVPSU1 In Curr not_available -- mA 0 mA -- 14100 mA 15000 mAPSU1 12V Out Volt not_available -- mV 10980 mV 11400 mV 12900 mV 13500 mVPSU1 12V Out Curr not_available -- mA 0 mA -- 165000 mA 173000 mAPSU1 In Pwr not_available -- W -- -- -- --PSU1 Out Pwr not_available -- W -- -- -- --PSU1 Type not_available --PSU1 need replacement NOTSUREPSU1 INFO FRU_AVAILPSU1 Power invalid --PSU1 Current invalid --PSU1 Voltage invalid --PSU2 GOODPSU2 FRU GOOD- 18.3P1以降を実行しているSPバージョン
Service Processor Status: Online Firmware Version: 18.3P2 Mgmt MAC Address: d0:39:ea:c8:38:95 Ethernet Link: up, 1Gbps Using DHCP: no