Cisco Nexus 313Vはネットアップから購入しました

問題

  • Cisco NX313取り込む すべてのLEDは、一度に1つずつ順番に点滅します
  • スイッチログからPSU1に関する再発生エラーが記録されます
[11.02.2022,  PM] 2022 Feb 10 08:42:50 switch %PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS1 changed its capacity. possibly due to On/Off or power cable removal/insertion
[11.02.2022,  PM] 2022 Feb 10 08:42:50 switch %PLATFORM-2-PS_ABSENT: Power supply 1 is absent/shutdown, ps-redundancy might be affected
[11.02.2022,  PM] 2022 Feb 10 08:42:50 switch %PLATFORM-2-PS_RED_MODE_CHG: Power supply operational redundancy mode changed to non-redundant
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-5-PS_FOUND: Power supply 1 found (Serial number PSU)
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-2-PS_OK: Power supply 1 ok (Serial number PSU)
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-5-PS_STATUS: PowerSupply 1 current-status is PS_OK
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-2-PS_FANOK: Fan in Power supply 1 ok
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-4-PFM_PS_RED_MODE_CHG: Power redundancy configured mode changed to ps-redundant
[11.02.2022,  PM] 2022 Feb 10 08:42:51 switch %PLATFORM-2-PS_RED_MODE_RESTORED: Power redundancy operational mode changed to configured mode
[11.02.2022,  PM] 2022 Feb 10 14:09:11 switch %PLATFORM-2-PS_REMOVE: Power supply 1 removed (Serial number PSU)
[11.02.2022,  PM] 2022 Feb 10 14:09:11 switch %PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS1 changed its capacity. possibly due to On/Off or power cable removal/insertion
[11.02.2022,  PM] 2022 Feb 10 14:09:11 switch %PLATFORM-2-PS_ABSENT: Power supply 1 is absent/shutdown, ps-redundancy might be affected
[11.02.2022,  PM] 2022 Feb 10 14:09:11 switch %PLATFORM-2-PS_RED_MODE_CHG: Power supply operational redundancy mode changed to non-redundant
[11.02.2022,  PM] 2022 Feb 10 14:09:12 switch %PLATFORM-5-PS_FOUND: Power supply 1 found (Serial number PSU)
[11.02.2022,  PM] 2022 Feb 10 14:09:12 switch %PLATFORM-2-PS_OK: Power supply 1 ok (Serial number PSU)
[11.02.2022,  PM] 2022 Feb 10 14:09:12 switch %PLATFORM-5-PS_STATUS: PowerSupply 1 current-status is PS_OK
[11.02.2022,  PM] 2022 Feb 10 14:09:12 switch %PLATFORM-2-PS_FANOK: Fan in Power supply 1 ok
  • 電源ケーブルと電源接続は正常です
  • スイッチPSU1のLEDは緑

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.