環境

  • FASシステム
  • AFFシステム
  • Ciscoスイッチ
  • Active IQ Digital Advisor

問題

  • Active IQリスクアラートを受信しました:
Risk: This system has a high count of CRC errors accumulated on at least one data network port that should be investigated.
Description: This system has CRC errors on data port e0e.

Impact: High CRC errors counts, or link resets can result in packet loss and are typically caused by physical defects in the port, SFP, or cables
  • ポートがデータスイッチに接続されている
  • IFSTAT-A AutoSupportのセクション、または cluster::> ifstat -a CRCエラーが表示された場合:
 
-- interface  e0e  (1 day, 1 hour, 11 minutes, 41 seconds) --

RECEIVE
Total frames:     6821k | Frames/second:      75  | Total bytes:      6681m
Bytes/second:    73660  | Total errors:      151  | Errors/minute:       0
Total discards:      0  | Discards/minute:     0  | Multi/broadcast:   254k
Non-primary u/c:     0  | CRC errors:        151  | Runt frames:         0
Long frames:         0  | Length errors:       0  | Alignment errors:    0
No buffer:           0  | Pause:               0  | Jumbo:               0
Noproto:             0  | Bus overruns:        0  | LRO segments:      399m
  • SFPが両側で交換されている
  • ノードとスイッチ間のケーブルが交換されました
  • ノードポートの統計がクリアされ、CRC errorsが返されます。
::>run -node * ifstat -z e0e

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.