問題

  • 起動時のエラー報告:

WARNING: The battery is unfit to retain data during a power
outage. This is likely because the battery is
discharged but could be due to other temporary conditions.
When the battery is ready, the boot process will
complete and services will be engaged.

To override this delay, press 'c' followed by 'Enter

  • リブートの直前にEMSで次のエラーが表示されました

Mar 24 06:49:59 [node:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (not present) CRITICAL.
Mar 24 06:51:00 [node:nvmem.battery.notPresent:ALERT]: The NVMEM battery is not present. To prevent data loss, the system will shut down in 5 minutes.

  • BMCから"system battery show"を実行すると、バッテリがないと報告される

BMC-01> system battery show
Battery pack is absent.

  • システムがバッテリパックを認識できません:

::> system node environment sensors show

Bat_Temp      | na     | degrees C  | na      | 0.000    | 5.000    | 56.000   | 60.000   
Bat_Volt      | na     | Volts    | na      | 5.500    | 5.600    | 8.500    | 8.600    
Bat_Curr      | na     | Amps     | na      | na     | na     | 1.520    | 1.800    
Bat_Rem_Cap    | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Full_Cap    | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Charge_Curr  | na     | Amps     | na      | na     | na     | 2.400    | 2.900    
Bat_Charge_Volt  | na     | Volts    | na      | na     | na     | 8.900    | 9.000    
Bat_Design_Cap   | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Initial_Fcc  | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Average_Temp | na     | degrees C  | na      | na     | na     | na     | na     
Bat_Rem_Cap_off  | na     | Amps * hour | na      | na     | na     | na     | na     
Bat_Dstg_Cycles  | na     | cycles    | na      | 2.000    | 5.000    | na     | na     
Bat_Power_Fault  | 0x0     | discrete   | Asserted   | na     | na     | na     | na     
Bat_Dsg_FET_Flt  | na     | discrete   | na      | na     | na     | na     | na     
Bat_Chg_FET_Flt  | na     | discrete   | na      | na     | na     | na     | na     
Bat_Pack_Invalid | na     | discrete   | na      | na     | na     | na     | na     
Bat_Cycle_Cnt   | na     | cycles    | na      | na     | na     | na     | na     
Bat_Lrn_Active   | na     | discrete   | na      | na     | na     | na     | na    

  • BMCを最新バージョンにアップグレードし、センサー出力を再確認してください。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.