環境

  • FAS2720
  • ONTAP 9.7P5
  • サービスプロセッサ ファームウェアバージョン:  11.8

問題

FAS2720にLots of Chassis powerアラートが表示されます。
 
EMS ログ:

Wed May 03 01:03:39 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 02:03:41 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 03:03:42 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 03:31:32 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 04:31:33 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 05:31:34 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 06:31:35 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 07:31:36 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 08:31:36 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 09:31:38 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 10:31:39 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).
Wed May 03 10:54:39 +0800 [Node-02: env_mgr: monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVTT DDR4 AB is critical high (660 mV).

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.