問題

  • シャーシの電源がデグレード状態の AutoSupport では引き続きアラートが発生し、デグレード状態と OK が切り替わります。

HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.) ERROR

HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR

HA Group Notification (CHASSIS POWER SUPPLY OK: PS 1) NOTICE

HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2.) ERROR

HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 2) ERROR

HA Group Notification (CHASSIS POWER SUPPLY OK: PS 2) NOTICE

  • EMS エラーには温度アラートが含まれています。
[?] Sat Aug 08 14:15:01 EDT [node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Warning Low (4 C)
[?] Sat Aug 08 14:15:03 EDT [node-01: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[?] Sat Aug 08 14:17:44 EDT [node-01: env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 1 is OK.
[?] Sat Aug 08 14:17:53 EDT [node-01: power_low_monitor: monitor.chassisPowerSupplies.ok:info]: Chassis power supplies OK.
  • 他のシャーシ PSU 、クラスタ内の他のノード、およびシェルフの温度がすべて低いため、しきい値の下限を警告します。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.