Last Updated:

環境

  • FAS9000  / AFF A700
  • ONTAP 9

問題

  •  SP-LATEST-IPMI でノードからP3Vバッテリのステータスが「critical low」と報告される:

tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
2   0x5    /chassis-1/controller-a/coin-1      ipmi P3V_BATT lower non-critical         1    Thu Jan  1 00:02:49 1970
3   0x5    /chassis-1/controller-a/coin-1      ipmi P3V_BATT lower critical           1    Thu Jan  1 00:02:49 1970

Fault Lights On:
       /chassis-1                                        2
       /chassis-1/controller-a                                  2
       /chassis-1/controller-a/coin-1

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
P3V Batt          critlow       0 mV    2100 mV    2200 mV    3400 mV    3500 mV

  • コイン型電池でFRU LEDが点灯していることが報告される

FRU LEDs status
======================
FRU LED ID 01 = PCM FAULT LED
FRU LED ID 03 = SYS FAULT LED
FRU LED ID 41 = Coin Cell FAULT LED
FRU LED ID 1 is on
FRU LED ID 3 is on
FRU LED ID 41 is on

  • ノードからRTCバッテリの残量が危険なレベルに達していると報告される 

[?] env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.